Administration and Programming Manual Issue 1.6
634
Table C-3 STATION DATA
BTN SUB-MENU RANGE DEFAULT REMARK
2 DSS/DLS MAP Station
PGM: 111 -Station Attributes I
1 Auto Speaker Selection 1: ON, 0: OFF ON
2 Call Forward 1: ON, 0: OFF OFF
3 DND
0: OFF, 1:ALL,
2:icm call only, 3:co
call only
OFF
4 Data Line Security 1: ON, 0: OFF OFF
5 Howler Tone 1: ON, 0: OFF ON
6 No Touch Answer 1: ON, 0: OFF OFF
7 Page Access 1: ON, 0: OFF OFF
8 Speaker/Headset Ring S/H/BOTH Speaker SPKR: Speakerphone
9 Speakerphone/Headset ON/OFF Speaker ON: Speakerphone
10 LCD Display LED Ring/MWI MWI
11 Loop LCR Account 1: ON, 0: OFF OFF
Station based LOOP LCR
authorization option
12 Call Coverage 1: ON, 0: OFF OFF
13 Call Coverage Delay Ring 0~9 0
14 Off-net Forward Disable 0:ENA, 1:DIS Enable
Off-net Forward Activation
(Except USA version)
15 Forced ICM Mode Change 1:ON, 0:OFF OFF
16 Active PTT Group 0~9
17 Station ICM Tenancy Group 1~15 1
18 VMIU/VMIB Board
Sequence Number
19 SIP User ID Table Index 000-140
000
Index to Station SIP Attributes
Table (PGM 126, Web only)
20 Camp on Tone 1: ON, 0: OFF ON
21 Serial DSS
1: Disable
0 : Enable
Enable
22 ICM Dial Tone Source
0: dial tone
1: Int/Ext 1
2: Ext 2
3: VSF
4~8:SLT MOH1~5
9~10:VSF
MOH2~3
dial tone
23 ICM Ring Back Tone Source
0: ring back tone
1: Int/Ext 1
2: Ext 2
3: VSF
4~8:SLT MOH1~5
9~10:VSF
MOH2~3
ring back
tone
24 UMS Attach Message 1: ON, 0: OFF ON
PGM: 112 - Station Attributes II
1 CO Call Time Tone 1: ON, 0: OFF OFF
2 Automatic Hold 1: ON, 0: OFF
ATD:ON
Others: OFF
3 CO Call Time Restriction 1: ON, 0: OFF OFF
4 CO Line Access EN/DIS ENABLE

Table of Contents

Other manuals for iPECS UCP

Related product manuals