Table 3.3.6.1-2 SYSTEM ATTRIBUTES II (PGM 161)
BTN ATTRIBUTE/DISPLAY DESCRIPTION RANGE DEFAULT
10
G711 PACKETIZATION(1ms)
(10/20/30) : 20
The G.711 voice frame packetization
time determines the interval at which
voice samples are packetized and
sent when the G.711 codec is used.
10/20/30 20
11
G723 PACKETIZATION(1ms)
(30/60) : 030
The G.723.1 voice frame
packetization time determines the
interval at which voice samples are
packetized and sent when the
30/60 030
12
NETWORK TIME/DATE
(0-2) : DISABLE
The system can use ISDN Network
time or NTP to synchronize time with
the ISDN or data network. To
disable time sync, use OFF. ISDN
sync is not available in USA version.
0~2 DISABLE
13
INCOMING TOLL CHK
(1:ON/0:OFF) : ON
The system can invoke COS dialing
restrictions when a user dials while
connected to incoming call.
0: OFF
1: ON
ON
14
WEB SERVER PORT
(00001-65535) : 00080
This field determines the TCP port
employed to access the system
00001~
65535
00080
15
UNUSED
16
OLD AUTH CODE USAGE
(1:ON/0:OFF) : ON
System Authorization codes are
entered by the user as “*” and the
code (ON) or “*”+ the Auth code
index and the code (OFF).
0: OFF
1: ON
ON
17
COS 7 WHEN AUTH FAIL
(1:ON/0:OFF) : OFF
If user fails to enter a valid
Authorization code in the number of
attempts assigned in FAC RETRY
COUNT, PGM 160-button 16, the
station is disconnected or the
Station COS is changed to COS 7.
In the latter case, the user must
employ COS Restore in Station User
PGM 2 to return the station to the
0: OFF
1: ON
OFF
18
UNIFIED MESSAGE FORMAT
(1:ON/0:OFF) : OFF
System Integration Messages are
sent out the defined serial or TCP
0: OFF
1: ON
OFF
19
RECORD WARNING TONE
(1:ON/0:OFF) : ON
When call recording is active, a tone
can be sent to all connected parties
to indicate the conversation is being
0: OFF
1: ON
ON
20
UNUSED
Unused. 0: OFF
1: ON
OFF