iPECS eMG80 & eMG800 & UCP
Administration and Programming Manual Issue 1.6
105
Table 3.3.6.1-2 SYSTEM ATTRIBUTES II (PGM 161)
BTN ATTRIBUTE/DISPLAY DESCRIPTION RANGE DEFAULT
21
UNUSED
Unused. 0: OFF
1: ON
OFF
22
SMS CENTER NUMBER
.......................
When the PSTN will be used to send
SMS, the phone number of the Short
Message Service Center must be
23 digits
23
SMS PROTOCOL
(0-8) : NONE (0)
The Short Message Service Protocol
must be selected to support SMS:
0: No PSTN SMS support,
1: ETSI-P1
2: ETSI-P2
3: KT-LivingNet
4: SIP-Text
5: SIP-XML
6: KT-IP-PBX
7: SKN-IP-PBX
0 ~ 8 NONE
24
SYSTEM 2 ADDED ATTR
PRESS FLEX KEY (1-23)
Select button 24 to access added
attributes 1~23.
FLEX 1 ~
FLEX 23
24-1
G722 PACKETIZATION(1ms)
(10/20/ 30) : 20
The G.722 voice frame packetization
time determines the interval at which
voice samples are packetized and
sent when the G.722 codec is used.
10/20/30msec
20
24-2
UNUSED
This filed is used only for KOREA.
24-3
SMS CENTER CLI
.......................
When the CO/IP will be used to
receive SMS, the Caller Id expected
from the Short MSG Service Center
23 digits
24-4
TRANSIT-OUT SECURITY
(1:ON/0:OFF) : ON
Check IP address for transit-out in
the master system, if it is not valid IP
address then it will be denied.
0: OFF
1: ON
ON
24-5
EMR CALL ATD NOTIFY
(1:ON/0:OFF) : ON
Provide notification to attendant
when user dials emergency number.
0: OFF
1: ON
ON
24-6
UNUSED
Unused. 0: LOCAL
1: MCIB_V
MCIB_V
24-7
FIRST DIGIT * IN SPD
DISPLAY SECURITY (0)
If it is ‘0’ then the first ‘*’ in speed will
be used for display security
otherwise DTMF ‘*’ will be send.
0: DISPLAY
SECURITY
DISPLAY
SECURITY
24-8
STRONG PASSWORD
(1:ON/0:OFF) :OFF
ON: Password in PGM162 must be
longer than 8 and made by
0: OFF
1: ON
ON