Table 4.4.5.1-1 SYSTEM ATTRIBUTES
ATTRIBUTE DESCRIPTION RANGE DEFAULT
Name List Only", the system speed dial number of Accessible
system speed zone (System Speed Zone (232)) is
displayed in {Dial by Name}.
Accessible
System Speed
Default Web Language
The user can select the display language used in the
Web pages. Either English or the “Local” language
can be selected. Note the “Local Language” must be
entered in the Multi-Language file in Maintenance
English/
Local language
English
No Range Load Limit
on Web Admin
OFF: Limited index range will be accepted (e.g. 1-
100)
ON: No limitation of table index (e.g. 221, 222, 270,
OFF/ON ON
Forward limitation by
caller COS
Caller (internal station) call to a station offnet
forwarded. It can be forwarded by caller COS if it's
OFF/ON OFF
No CLI Call Log
Leave system Call log even though there is no CLI
information if it is ON. Otherwise Call log is not
OFF
ON
OFF
Remote VM Forward
Access
If the value is ON, Call Forwarding setting from
remote access is enabled. If the value is OFF, Call
Forwarding setting from remote access is disabled.
OFF
ON
ON
DB Backup to USB
monthly
System downloads the database to USB periodically.
The user can access, copy and delete files in USB
drive via web admin. So you can back up DB by
choosing the specific date for Monthly or Weekly.
N/A,
1,
DB Backup to USB
N/A,
SLT Line Monitor
SLT line supervision is to be supported to check the
line connection/disconnection periodically as
programmed - daily or programmed time. When the
line is disconnected, alarm call/message notification is
provided to pre-defined destinations like other alarms.
System will send e-mail notification according to
"Common SMTP Attributes" and "Alarm Attributes".
This is to provide more reliability for mission-critical
services for hospitality or health care solutions (i.e.
bath alarms using SLT line).
Conditions
- Normal SLT service is not available during detection
period since the detection takes several seconds.
- Ringer test determines the presence of appropriate
ringer terminations on the line. The measured
impedance must be within the defined limits: 1.4 kΩ
(5 REN) ~ 40 kΩ (0.175 REN). Otherwise the test
fails, which means that normal SLT device can be
detected, but if simple device which does not provide
the proper ringer impedance is connected, then we
cannot detect it properly.
- Supported system options: UCP/eMG80/800 with
OFF
ON
OFF