iPECS eMG80 & eMG800 & UCP
Administration and Programming Manual Issue 1.6
384
Table 4.4.5.20-1 SYSTEM TIMERS
ATTRIBUTE DESCRIPTION RANGE DEFAULT
4 digits received as DID digits.
R2 Out Manage Timer Reserved for future usage for R2 timers.
01~50
14
R2 In Manage Timer Reserved for future usage for R2 timers.
01~50
14
R2 Disappear Timer Reserved for future usage for R2 timers.
01~50
14
R2 Pulse Timer Reserved for future usage for R2 timers.
01~30
7
R2 Ready Timer Reserved for future usage for R2 timers.
000~500
7
Dial Tone Delay Timer Reserved for future usage for R2 timers.
01~30
20
Wake Up Fail Timer
At expiration of this timer, the system will notify the
Attendant when a user does not respond to a Wake up
00~99 20
VSF Cut Error Tone
Timer
The duration of Voice Messages in the built-in Voice
Mail are reduced by this timer to remove error tone that
may be sent by the carrier after disconnect.
00~90
(seconds)
0
On Hook Auto Idle
Timer
When an iPECS IP or LDP Phone receives a
disconnect message or signal from CO line the phones
goes to idle after this timer.
00~99
(seconds)
0
IP Watch Timer
When Local redundancy is implemented, should the
LAN cable fail, both call servers may attempt to be
active. To protect against this “dual active” case, the
system can periodically check for an active back-up
0~250
(1 sec.)
0
Prepaid Call Drop
Warning Timer
When the Prepaid funds are exhausted, the user will
receive a warning tone indicating the call will be
dropped after this timer expires.
00-99 10
Emergency retry timer
System try to make emergency call according to the CO
access rule/Prefer CO/CO group if system could not
seize predefined emergency Co line within this timer.
00~99
(seconds)
0
Record Warning
If record warning tone is set and this timer is set greater
than 1, it works periodically when it’s recorded.
000~999
0
Error Tone Timer This timer sets the duration for Error Tone.
5~180
30
Howling Tone Timer This timer sets the duration for Howling Tone.
0~180
30
VM Notify Play Delay
Over CO Timer
When VM notification to the mobile uses an analog loop
start Line, system will treat the call as the answered
after this timer and play the new message prompt.
1~99
(1 sec.)
10
Fax Detect timer
It is maximum fax tone detection time to deliver FAX
1~20
10
Auto Pause Release
IPCR Mute function will be released by this auto pause
0~255
0
UCS Ring ACK Timer
UCS Client is ringing before expiring the Ring ACK
timer and afterwards will hear Error tones.
0~20
0
If {Short modem} of a SLT is ON, the SLT maintains the