EasyManua.ls Logo

iPECS UCP - Page 430

iPECS UCP
689 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iPECS eMG80 & eMG800 & UCP
Administration and Programming Manual Issue 1.6
415
Table 4.4.6.3-2 ACD GROUP ATTRIBUTES
ATTRIBUTE DESCRIPTION RANGE DEFAULT
CIQ Display To
Agent - Mode
When an ACD call is in queue, the Call in queue
information is displayed in the LCD of agent and
supervisor phones.
OFF
ON
OFF
CIQ #1 Page Alert -
Threshold
If the queued call count exceeds the threshold, the
system plays the CIQ #1 Announcement to the CIQ #1
Page Zone after the CIQ #1 Announcement Delay
Timer. The announcement is repeated at intervals of the
CIQ #1 Announcement Repeat Timer.
00-99 10
CIQ #1 Page Alert
Announcement
Location
VSF announcement number for the CIQ #1
Announcement.
00-200 0
CIQ #1 Page Alert
Page Zone
Page Zone to receive CIQ #1 Announcement.
eMG80:00~15 or
00-40/
eMG800:0~105/
UCP:0~105
00
CIQ #1 Page Alert -
Delay Time
Delay timer for CIQ #1 Announcement 000-180 015
CIQ #1 Page Alert -
Repeat Time
Interval for repeating the CIQ #1 Announcement. 000-180 045
CIQ #2 Page Alert -
Threshold
If the queued call count exceeds the threshold, the
system plays the CIQ #2 Announcement to the CIQ #2
Page Zone after the CIQ #2 Announcement Delay
Timer. The announcement is repeated at intervals of the
CIQ #2 Announcement Repeat Timer.
00-99 20
CIQ #2 Page Alert -
Announcement
Location
VSF announcement number for the CIQ #2
Announcement.
00-200 0
CIQ #2 Page Alert
Page Zone
Page Zone to receive CIQ #2 Announcement.
eMG80:00~15 or
00-40/
eMG800:0~105/
UCP:0~105
00
CIQ #2 Page Alert -
Delay Time
Delay timer for CIQ #2 Announcement 000-180 015
CIQ #2 Page Alert -
Repeat Time
Interval for repeating the CIQ #2 Announcement. 000-180 025
CIQ #3 Page Alert -
Threshold
If the queued call count exceeds the threshold, the
system plays the CIQ #3 Announcement to the CIQ #3
Page Zone after the CIQ #3 Announcement Delay
Timer. The announcement is repeated at intervals of the
CIQ #3 Announcement Repeat Timer.
00-99 30
CIQ #3 Page Alert -
Announcement
Location
VSF announcement number for the CIQ #3
Announcement.
00-200 0
CIQ #3 Page Alert -
Page
Zone
Page Zone to receive the CIQ #3 Announcement.
eMG80:00~15 or
00-40/
eMG800:0~105
UCP:0~105
00
CIQ #3 Page Alert -
Delay Time
Delay timer for the CIQ #3 Announcement 000-180 015

Table of Contents

Other manuals for iPECS UCP

Related product manuals