EasyManua.ls Logo

iPECS UCP - Page 653

iPECS UCP
689 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iPECS eMG80 & eMG800 & UCP
Administration and Programming Manual Issue 1.6
638
Table C-3 STATION DATA
BTN SUB-MENU RANGE DEFAULT REMARK
24-23 Short Modem 1: ON, 0: OFF OFF
PGM: 115 - Flexible Buttons Assignment
01~
24
Flexible Buttons Assignment 1: Empty Button
2: Station PGM
Button
3: {Speed Dial
xx}Button
4: Numbering Plan
Button
5: Network DSS
Number
6: MSN Number
PGM: 116 - Station COS
1 Station COS: Day Ring 1~11 1
2 Station COS: Night Ring 1~11 1
3 Station COS: Timed Ring 1~11 1
PGM: 117 - CO Line/IP Channel Group Access
CO/IP Group 01~20 1
PGM: 118 - Internal Page Zone Access
Internal Page Zone Access 001-024 Group 01
PGM: 119 - PTT Group Access
PTT Page Zone 01~10
PGM: 120 - Preset Call Forward
Preset Call Forward 1~8 + destination -
1: Unconditional Forward
2: Internal Busy Forward
3: Internal No Answer Forward
4: External Busy Forward
5: External No Answer
Forward
6: Voice Mail box
7: Internal DND
8: External DND
PGM: 121 - Idle Line Selection
Type 1~7 -
1: Flex Button
2: CO Line
3: CO Group
4: Station Number
5: Hunt Group
6: Station Speed
7: System Speed
PGM: 122 – Station IP Attributes
1 Direct IP Call EN/DIS ENABLE
PGM: 123 - Station Timers
1 Station Fwd No-Answer Timer 000~600 000 1 second increments
2 Cur off timer 00~99 00 1 minute increments

Table of Contents