Administration and Programming Manual Issue 1.6
648
Table C-6 SYSTEM DATA
BTN SUB-MENU RANGE DEFAULT REMARK
18 Unified Message Format 1: ON, 0: OFF OFF
19 Record Warning Tone 1: ON, 0: OFF ON
20 Unused
21 Unused
22 SMS CENTER NUMBER 23 digits
23 SMS PROTOCOL 0 ~ 8 NONE
0: No PSTN SMS support,
1: ETSI-P1
2: ETSI-P2
3: KT-LivingNet
4: SIP-Text
5: SIP-XML
6: KT-IP-PBX
7: SKN-IP-PBX
8: KT XML
24 ADDED ATTR
24-1 G.722 PACKETIZATION(1ms) 10/20/30 msec 20
24-2 Unused
24-3 SMS CENTER CLI 23 digits
24-4 TRANSIT-OUT SECURITY 1: ON, 0: OFF ON
24-5 EMR CALL ATD NOTIFY 1: ON, 0: OFF ON
24-6 Unused
24-7 FIRST DIGIT * IN SPD
0: DISPLAY
SECURITY
1: DIGIT *
DISPLAY
SECURITY
24-8 Strong password 1: ON, 0: OFF ON
24-9 VSF/VMIB SMTP PORT 0 65535 25
24-10 ICM BUSY SVC
1: OHVO,
0: INTR
OHVO
24-11 AUTO SAVE NEW MSG 1: ON, 0: OFF OFF
24-12 IGMP QUERY USAGE 1: ON, 0: OFF OFF
24-13 IGMP INTV_TMR(1sec)
0~3600 (Sec.) 180
24-14 IGMP QUERY ALL HOSTS 1: ON, 0: OFF ON
24-15 IGMP QUERY GENERIC 1: ON, 0: OFF OFF
24-16 RING-GROUP INDICATION 1: ON, 0: OFF OFF
24-17 RESTRICT * AND # 1: ON, 0: OFF OFF
24-18 RESTRICT ANS DGT DISP 1: ON, 0: OFF ON
24-19 IP BIND USAGE 1: ON, 0: OFF OFF
24-20 ACD MAILSEND WEEKLY SET 0-7 0
24-21 ACD MAILSEND DAILY SET 00-23
24-22 ACD DEL AFTER MAILSEND 1: ON, 0: OFF OFF
24-23 NEW 5 WAKE UP USAGE 1: ON, 0: OFF OFF
24-24 ACD GROUP INDICATION
0: OFF,
1: ON RING,
2: ON LED
OFF
PGM: 162 - System Password
1 Admin Password Max 12 digits -
2 Maintenance Password Max 12 digits -
PGM: 163 - Alarm Attributes