Configuration
3.2 Load and Save
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
102 Configuration Manual, 11/2015, C79000-G8976-C252-10
Overview of the file types
File type
Description
Config
Start configuration
ConfigPack Detailed configuration information. for example, start configuration, users,
certificates
Debug
This file contains information for Siemens Support.
Firmware Firmware
GSDML
Information on the device properties
HTTPSCert
HTTPS certificate
LogFile
File with entries from the event log table
MIB
Private MSPS MIB file "Scalance_w_msps.mib"
RunningCLI This file contains an overview of the current configuration in the form of CLI
commands. You can download the text file. The file is not intended to be up-
loaded again unchanged.
Script
CLI script file
StartupInfo
Startup log file
Users
File with user names and passwords
3.2.1
The "show" commands
This section describes commands with which you display various settings.
3.2.1.1
show loadsave files
Description
This command shows the current Load&Save file information.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
show loadsave files
Result
The current Load&Save file information is displayed.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals