Configuration
3.4 Configuration Save & Restore
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
117
The selected configuration settings of the device are displayed.
Commands in the global configuration mode
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
configure terminal command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
end or exit command and are then in the
Privileged EXEC mode again.
The CLI can save changes to the configuration automatically.
If you first want to test changes made to the configuration so that you can discard them
afterwards if necessary, you can disable the auto save function.
You are then in the Trial mode.
Changes to the configuration that you have not saved, are indicated by an asterisk in front of
the command prompt:
*cli(...)#.
You save the changes to the configuration with the
write startup-config command.
With the
auto-save command, you enable the auto save function.
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Call the command without parameters:
auto-save
As default the function is "enabled".
The auto save function is enabled.