Configuration
3.2 Load and Save
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
110 Configuration Manual, 11/2015, C79000-G8976-C252-10
The firmware is signed and encrypted. This ensures that only firmware created by Siemens
can be downloaded to the device.
With this command, you load a file from a TFTP server into the file system of the device. The
TFTP protocol is used for the transfer. You can also display a list of available files.
● The name of the file is specified
● You are in the LOADSAVE configuration mode.
The command prompt is:
cli(config-loadsave)#
Call up the command with the following parameters:
tftp load{showfiles|filetype<filetype>}
The parameters have the following meaning:
Shows the available files
Keyword for a file type to be loaded
The file types are displayed or the file is downloaded to the device.
You configure the name of the file with the tftp filename command.
With the "
show loadsave files" command, you can display the file types.