Configuration
3.5 PoE
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
129
Requirement
You are in the Interface configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-Gi$-$)#
The placeholders $-$ stand for the numbering of the interface.
Syntax
Call up the command with the following parameters:
poe prio {low|high|critical}
The parameters have the following meaning:
Parameter
Description
low
low priority
high
medium priority
critical
high priority
Result
The priority of the corresponding interface has been specified.
3.5.3.11
no poe prio
Description
With this command, you set the priority of an interface to the default value "low".
Requirement
You are in the Interface configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-Gi$-$)#
The placeholders $-$ stand for the numbering of the interface.
Syntax
Call the command without parameters:
no poe prio
Result
The priority of the corresponding interface has been set to "low".