Configuration
3.5 PoE
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
122 Configuration Manual, 11/2015, C79000-G8976-C252-10
Further notes
You configure the value for the parameter "Maximum Power" with the poe pse MaximumPower
command.
3.5.2.3
poe pse usage
Description
With this command, you set a value (as a percentage) for the "Usage Threshold" parameter.
This specifies how many percent of the maximum power the connected devices will use. As
soon as the power being used by the end devices exceeds this percentage, an event is
triggered. An event is also entered in the log. You display the entries of the log with the
command
show logbook. You will find more information on this command in the section
"show logbook (Page 762)".
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
poe pse usage <percent>
The parameters have the following meaning:
Parameter
Description
percent
Value for "Usage Threshold" as a percentage.
Result
The value for "Usage Threshold" is configured.
3.5.2.4
no poe pse usage
Description
With this command, you set the "Usage Threshold" parameter to the default value of 80%.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals