Load control
10.4 Flow control
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
666 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call the command without parameters:
no mac-address-table aging
Result
The "Aging" function is disabled.
Further notes
You enable the "Aging" function with the mac-address-table aging command.
10.4
Flow control
The flow control function monitors the incoming data traffic of a port. If there is overload
("Congestion", "Overflow") it sends a signal to the connection partner. If the flow control
function receives a signal at the sending end, it stops the data transmission to avoid loss of
data.
This section describes commands of the flow control function.
10.4.1
The "show" commands
This section describes commands with which you display various settings.
10.4.1.1
show flow-control
Description
This command shows the settings of the flow control function.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals