System time
5.3 SNTP Client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
159
5.3.3.2
sntp time diff
Description
With this command, you configure the time difference of the system time relative to the UTC
time.
Requirement
The SNTP server must have started up.
You are in the SNTP Configuration mode.
The command prompt is:
cli(config-sntp)#
Syntax
Call up the command with the following parameters:
sntp time diff <(+/-hh:mm)>
The parameter has the following meaning:
Parameter
Description
+
Time zones to the west of the SNTP server time zone
-
Time zones to the east of the SNTP server time zone
hh
Number of hours difference
mm
Number of minutes difference
Enter the time difference as follows:
with sign
without spaces
Hours and minutes both two digits (with leading zero)
Default: no time difference
Result
The time zone of the system time is configured.
Further notes
You can display the settings of this function and other information with the show sntp
status
command.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals