Configuration
3.5 PoE
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
127
Requirement
You are in the Interface Configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-Gi$-$)#
The placeholders $-$ stand for the numbering of the interface.
Syntax
Call the command without parameters:
no poe custom maxpwr active
Result
The user-defined maximum power is disabled for the relevant interface.
Further notes
You configure the user-defined maximum power for an interface with the poe custom maxpwr
command.
You enable the use of the user-defined maximum power with the
poe custom maxpwr active
command.
3.5.3.8
poe type
Description
This command specifies a character string that describes a connected device in greater
detail.
Requirement
You are in the Interface configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-Gi$-$)#
The placeholders $-$ stand for the numbering of the interface.