Configuration
3.1 System
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
69
Syntax
Call up the command with the following parameters:
clear counters [<interface-type><interface-id>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
interface-type
Type or speed of the interface
Specify a valid interface.
interface-id
Module no. and port no. of the interface
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 39)".
If no parameters are specified, the counters for all interfaces are reset.
Result
The counters of the interface are reset.
Further notes
You can display the statistical information of the interfaces with the show interfaces -
counters
command.
3.1.3
clear line vty
Description
With this command, you close a console session on the device.
With the
forceful-clear option, you close a session and that is not reacting.
Requirement
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals