EasyManuals Logo

Siemens SCALANCE XR-500 Configuration Manual

Siemens SCALANCE XR-500
832 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #279 background imageLoading...
Page #279 background image
Network protocols
7.2 IPv6 protocol
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
279
7.1.3.4
dcp forwarding
Description
With this command, you configure the forwarding behavior of the interface for DCP frames.
Note
PNIO configuration
Since DCP is a PROFINET protocol, the configuration created here is only effective with the
VLAN associated with the TIA interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
dcp forwarding {block|forward}
The parameters have the following meaning:
Parameter
Description
Range of values / note
block
DCP frames are discarded
-
forward
DCP frames are forwarded
Default: forward
Result
The forwarding behavior of the interface for DCP frames is configured.
7.2
IPv6 protocol
This section describes the commands relevant for working with IPv6.
7.2.1
clear ipv6 traffic
Description
With this command, you reset the statistics counters to zero.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals