Diagnostics
12.1 Event and fault handling
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
760 Configuration Manual, 11/2015, C79000-G8976-C252-10
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Call the command without parameters:
show events severity
The corresponding degree of severity is shown for each type of notification.
You configure the assignment of the degree of severity of an event and the type of
notification with the
severity command.
show events faults config
Description
This command shows the current configuration of the following error monitoring functions:
● Monitoring of the power supply for power outage
● Monitoring of the network connections for a change in the connection status
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Call up the command with the following parameters:
show events faults config [{power|link}]
The parameters have the following meaning:
Monitoring of the power supply for power outage
Monitoring of the network connections for a change in the connection status
If no parameters are specified, the settings for both error monitoring functions are displayed.