Diagnostics
12.5 RMON
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
809
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Call the command without parameter assignment:
no rmon
Default: disabled
The Remote Monitoring function is disabled.
You enable this function with the rmon command.
You can display the status of this function and other information with the
show rmon
command.
With this command, you configure an alarm for monitoring a MIB variable. The variable is
checked at specific intervals to determine whether or not it has exceeded or fallen below
threshold values. Events are assigned to these occurrences.
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#