Network protocols
7.6 DHCPv6 Relay Agent (IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
334 Configuration Manual, 11/2015, C79000-G8976-C252-10
Further notes
You enable the DHCPv6 relay agent with the ipv6 dhcp relay. command.
You display the information with the
show ipv6 dhcp relay information command.
7.6.3
Commands in the global configuration mode
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
configure terminal command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
end or exit command and are then in the
Privileged EXEC mode again.
7.6.3.1
ipv6 dhcp relay remote-id
Description
With this command, you specify whether the DHCP relay agent option 37 (Remote ID) is
used.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ipv6 dhcp relay remote-id {enable | disable}
The parameters have the following meaning:
Parameters
Description
Range of values / note
enable
Remote ID is used
-
disable
Remote ID is not used
-
Result
The Remote ID is activated.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals