Configuration
3.5 PoE
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
126 Configuration Manual, 11/2015, C79000-G8976-C252-10
Further notes
You configure the user-defined maximum power for the interface with the poe custom maxpwr
command.
You enable the user-defined maximum power for the interface with the
poe custom maxpwr
active
command.
You disable the user-defined maximum power for the interface with the
no poe custom
maxpwr active
command.
3.5.3.6
poe custom maxpwr active
Description
With this command, you enable use of the user-defined maximum power for the interface.
Requirement
You are in the Interface Configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-Gi$-$)#
The placeholders $-$ stand for the numbering of the interface.
Syntax
Call the command without parameters:
poe custom maxpwr active
Result
The user-defined maximum power is enabled for the relevant interface.
Further notes
You configure the user-defined maximum power for an interface with the poe custom maxpwr
command.
You disable the use of the user-defined maximum power with the
no poe custom maxpwr
active
command.
3.5.3.7
no poe custom maxpwr active
Description
With this command, you disable use of the user-defined maximum power for the interface.