Security and authentication
11.7 Port Based Network Access Control
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
752 Configuration Manual, 11/2015, C79000-G8976-C252-10
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
dot1x mac-auth vlan-assign
Result
The VLAN ID for a MAC address is assigned by the RADIUS server.
11.7.3.11
no dot1x mac-auth vlan-assign
Description
With this command you disable the assignment of the VLAN ID for a MAC address by the
RADIUS server.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no dot1x mac-auth vlan-assign
Result
The VLAN ID for a MAC address is no longer assigned by the RADIUS server.
11.7.3.12
dot1x port-control
Description
With this command, you configure port control parameter of the authenicator.