Description
2.3 Configuration limits
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
34 Configuration Manual, 11/2015, C79000-G8976-C252-10
Privileged EXEC mode
You change to this mode if you log in with the name "admin" or enter the command enable in
User EXEC mode. There are two ways of exiting the Privileged EXEC mode:
1. The
exit command logs you out; the Login Prompt prompt appears.
2. The
disable command brings you back one level from the Privileged EXEC mode to the
User EXEC mode. (The
disable command is not available in the User EXEC mode.)
Global configuration mode
In this mode, you can make basic configuration settings. In addition to this, you can also call
up modes for the configuration of special interfaces or functions, for example to configure a
VLAN or a C-PLUG. You change to this mode by entering
configure terminal in the
Privileged EXEC mode. To exit this mode, enter
end.
Other configuration modes
From the Global configuration mode, you can change to other configuration modes for
special tasks. These are either general configuration modes (for example line configuration,
interface configuration) or protocol-specific configuration modes (SNTP, NTP).
2.3
Configuration limits
Configuration limits of the device
The following table lists the configuration limits for Web Based Management and the
Command Line Interface of the device.
The usability of various functions depends on the device type you are using and whether or
not a KEY-PLUG is inserted.
Configurable function
Maximum number
System
Syslog server
3
E-mail server 3
SNMPv1 trap recipient
10
SNTP server
1
NTP server
1
Layer 2
Virtual LANs (port-based; including VLAN 1)
257
Protocol-based VLAN groups
12
Protocol-based VLAN groups per port
12
IPv4 subnet-based VLANs
150
Multiple Spanning Tree instances
16
Link aggregations or Etherchannels each with a maximum of 8
ports per aggregation
8
Ports in a link aggregation
8

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals