Page #286 background image
Network protocols
7.2 IPv6 protocol
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
286 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call up the command with the following parameters:
no ipv6 neighbor <prefix>
{vlan <id> | [<interface-type> <interface-id>]}
<MAC ADDRESS (xx:xx:xx:xx:xx:xx)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
prefix
IPv6 address of the neighbor node
Enter a valid IPv6 address.
vlan
Keyword for a VLAN connection -
id
Number of the addressed VLAN
1 ... 4094
interface-type
Type or speed of the interface
Enter a valid interface.
interface-id
Module no. and port no. of the interface
MAC ADDRESS
Link layer address (MAC address) of the neighbor node xx:xx:xx:xx:xx:xx
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 39)".
Result
The entry is deleted.
Further notes
You configure an entry with the no ipv6 neighbor command.
You display the IPv6 neighbor table with the
show ipv6 neighbors command.
7.2.3.3
ipv6 path mtu
Description
With this command, you configure maximum packet size (MTU). The setting is only effective
if PMTU Discovery is enabled.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals