Configuration
3.5 PoE
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
128 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call up the command with the following parameters:
poe type <string>
The parameters have the following meaning:
Parameter
Description
Range of values / note
string
Description of a connected device
max. 255 characters
Result
The description of the connected device has been specified.
3.5.3.9
no poe type
Description
With this command, you delete the description for a connected device.
Requirement
You are in the Interface Configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-Gi$-$)#
The placeholders $-$ stand for the numbering of the interface.
Syntax
Call the command without parameters:
no poe type
Result
The description of the corresponding device is deleted.
3.5.3.10
poe prio
Description
With this command, you specify the priority of the power supply for an interface.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals