Configuration
3.5 PoE
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
128 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call up the command with the following parameters:
poe type <string>
The parameters have the following meaning:
Parameter
Description
Range of values / note
string
Description of a connected device
max. 255 characters
Result
The description of the connected device has been specified.
3.5.3.9
no poe type
Description
With this command, you delete the description for a connected device.
Requirement
You are in the Interface Configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-Gi$-$)#
The placeholders $-$ stand for the numbering of the interface.
Syntax
Call the command without parameters:
no poe type
Result
The description of the corresponding device is deleted.
3.5.3.10
poe prio
Description
With this command, you specify the priority of the power supply for an interface.