Layer 3 functions
9.2 OSPFv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
469
Further notes
You enable the function with the default-information originate command.
9.2.3.15
default-information originate always
Description
With this command, you enable the function with which a standard route is always generated
for external routes into the OSPF routing domain.
Note
This command is availa
ble only with layer 3.
Requirement
You are in the OSPF Router configuration mode.
The command prompt is as follows:
cli(config-ospf)#
Syntax
Call up the command with the following parameters:
default-information originate always
[metric <metric-value (0-0xffffff)>]
[metric-type <type (1-2)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
metric
Keyword for the metric of the external
standard route.
--
metric-value
Value of the metric
0-0xffffff
metric-type
Keyword for the type of the external
standard route
--
type
Type of the external route
1 - type 1
External and internal costs
2 - type 2
External costs
Result
The function is enabled.