SCALANCE XM-400/XR-500 Command Line Interface (CLI)
74 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call up the command with the following parameters:
ping [ip]<destination-address>
[size<byte(0-2080)>]
[count<packet_count(1-10)>]
[timeout<seconds(1-100)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
ip
Uses an IPv4 address
-
destination-address
Address of the called node Enter a valid IPv4 address or a
valid host name.
size
Keyword for the size of the packets to
be transferred
-
byte
Keyword for the size of the packets in
bytes
0 … 2080
Default: 32
count
Keyword for the number of packets to
be requested
-
packet_count
Number of packets 1 … 10
Default: 3
timeout
Response wait time
If this time expires, the request is re-
ported as "timed out".
-
seconds
Time to the timeout in seconds 1 … 100
Default: 1
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 39)".
If you do not select any parameters from the parameter list, the default values are used.
Result
The messages relating to the response of the called node are displayed.
3.1.10
ping ipv6
Description
With this command, you request a response from a device in the network. This allows you to
check whether or not another node is reachable.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals