Configuration
3.1 System
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
75
Requirement
IPv6 is enabled.
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call up the command with the following parameters:
ping ipv6 <prefix%interface>
[repeat <count>]
[size <value>]
[anycast]
[source {vlan <id> | <source_prefix>}]
[timeout <value (1-100)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
prefix
IPv6 address of the destination
Enter a valid IPv6 address.
%interface
optional parameter
Only necessary when the IPv6 ad-
dress of the destination is a link-local
address.
Specify the interface via which the
packet will be sent.
repeat
Keyword for the number of packets
to be requested
-
count
Number of packets 1 … 10
Default: 5
size
Keyword for the size of the packets
to be transferred
-
value
Packet size 0 … 2080 bytes
Default: 100
anycast
Addressing mode anycast
-
source
Keyword for the sender interface
VLAN
source_prefix
-
vlan
Keyword for a VLAN connection
-
id
Number of the addressed VLAN
1 ... 4094
source_prefix
Prefix of the sender
-
timeout
Response wait time
If this time expires, the request is
reported as "timed out".
-
value
Time until timeout 1 ... 100 s
Default: 5