Diagnostics
12.1 Event and fault handling
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
769
Result
The function of the client selected for the transfer is enabled.
Further notes
You display the status of the events and the clients with the show events config command.
You disable a client with the
no client config command.
12.1.6.3
no client config
Description
With this command, you disable one of the clients that processes or forwards the messages
of the device.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no client config {syslog|trap|email|all}
The parameters have the following meaning:
Parameter
Description
syslog
Disables the client that sends the messages to the Syslog server
trap
Disables the client that sends the SNMP traps
email
Disables the client that sends the e-mails
all
Disables all clients at once
Result
The client selected for the transfer is disabled.
Further notes
You display the status of the events and the clients with the show events config command.
You enable the function with the
client config command.