Layer 2 management protocols
8.4 Ring redundancy and standby connection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
416 Configuration Manual, 11/2015, C79000-G8976-C252-10
8.4.6.8
standby wait-for-partner
Description
With this command, you enable the "Wait for standby partner" function on the device. A
standby connection is enabled only after the standby master and the standby slave as well
as their standby partners have established a connection. This ensures that the redundant
connection is really available before communication via a standby connection is enabled. As
default, this function is enabled.
Requirement
You are in the Redundancy configuration mode.
The command prompt is as follows:
cli(config-red)#
Syntax
Call the command without parameters:
standby wait-for-partner
Result
The "Wait for standby partner" function is enabled.
8.4.6.9
no standby wait-for-partner
Description
With this command, you disable the "Wait for standby partner" function on the device. A
standby connection is enabled even if the standby master has not yet established a
connection to the standby slave.
Requirement
You are in the Redundancy configuration mode.
The command prompt is as follows:
cli(config-red)#
Syntax
Call the command without parameters:
no standby wait-for-partner

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals