Layer 2 management protocols
8.4 Ring redundancy and standby connection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
415
Further notes
You disable the setting with the no standby port command.
You display the status of this function and other information
show ring-redundancy.
8.4.6.7
no standby port
Description
With this command, disable the port for a standby connection on a device.
Requirement
You are in the Redundancy configuration mode.
The command prompt is as follows:
cli(config-red)#
Syntax
Call up the command with the following parameters:
no standby port [<interface-type><interface-id>}
The parameters have the following meaning:
Parameter
Description
Range of values / note
interface-type
Type or speed of the interface
Enter a valid interface.
interface-id
Module no. and port no. of the interface
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 39)".
Result
The ports for a standby connection are disabled.
Further notes
You enable the setting with the standby port command.
You display the status of this function and other information
show ring-redundancy.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals