Configuration
3.1 System
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
85
3.1.12.11
username
Description
With this command, you change the password of the factory set default users "user" and
"
admin".
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
username {user|admin} password <passwd>
The parameters have the following meaning:
Parameter
Description
Range of values / note
user
User name of the default user with
read access to the configuration
data.
-
admin
User name of the default user with
read and write access to the con-
figuration data.
-
password
Keyword for a password
-
passwd
Value for the password Enter the password.
The password must meet the following
password policies:
• Password length: at least 8 characters
• at least 1 uppercase letter
• at least 1 special character
• at least 1 number
Result
The password is changed.
Note
Changing the password in Trial mode
Even if you change the password in Trial mode, this change is saved immediately.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals