Configuration
3.1 System
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
73
3.1.8
logout
Description
With this command, you exit the Command Line Interface.
If you are connected to the device via telnet, the session is closed.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
logout
Result
The CLI session is ended and the Windows Login prompt is displayed.
3.1.9
ping
Description
With this command, you request a response from a device in the network.
This allows you to check whether or not another node is reachable.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#