Layer 2 management protocols
8.2 IGMP snooping
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
391
8.1.2.4
no gvrp
Description
With this command, you disable the GVRP function for all or individual interfaces on the
device.
Requirement
You are in the Global configuration mode
or
You are in the Interface configuration mode
The command prompt is as follows:
cli(config)#
cli (config-if-$$$) #
Syntax
Call the command without parameters:
no gvrp
Result
In the Global configuration mode: The GVRP function is disabled on the device.
In the Interface configuration mode: The GVRP function is disabled for this interface.
Further notes
If you want to enable the function for a specific interface on the device, use the gvrp
command.
You can display the status of this function and other information with the
show vlan device
info
command.
8.2
IGMP snooping
This section describes the snooping functionality of the Internet Group Management
Protocol.
8.2.1
The "show" commands
This section describes commands with which you display various settings.