Layer 2 management protocols
8.4 Ring redundancy and standby connection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
414 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call the command without parameters:
no standby force-master
Result
The standby force-master function is disabled.
Further notes
You enable the setting with the standby force-master command.
You can display the status of this function and other information with the
show ring-
redundancy
command.
8.4.6.6
standby port
Description
With this command, you configure and enable the port for a standby connection on a device.
Requirement
You are in the Redundancy configuration mode.
The command prompt is as follows:
cli(config-red)#
Syntax
Call up the command with the following parameters:
standby port {<interface-type> <interface-id>}
The parameters have the following meaning:
Parameter
Description
Range of values / note
interface-type
Type or speed of the interface
Enter a valid interface.
interface-id
Module no. and port no. of the interface
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 39)".
Result
The ports for a standby connection are configured and enabled.