Layer 3 functions
9.2 OSPFv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
489
9.2.4.9
ip ospf hello-interval
Description
With his command, you specify the interval between two Hello packets.
Note
This command
is available only with layer 3.
Requirement
The interface is an IPv4 interface.
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
ip ospf hello-interval <seconds (1 - 65535)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
seconds
Interval in seconds
0 ... 65535
Result
The interval is specified.
Further notes
You delete the interval with the no ip ospf hello-interval command.
You show the configuration of the OSPF interface with the
show ip ospf interface
command.