EasyManuals Logo

Siemens SCALANCE XR-500 Configuration Manual

Siemens SCALANCE XR-500
832 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #224 background imageLoading...
Page #224 background image
Network structures
6.3 Spanning Tree
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
224 Configuration Manual, 11/2015, C79000-G8976-C252-10
6.3.4.4
no spanning-tree compatibility
Description
With this command, you reset the compatibility version of the protocol of the spanning tree
function to the default value.
The default value is MST.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no spanning-tree compatibility
Result
The compatibility version is reset to the default value.
Further notes
You configure the setting with the spanning-tree compatibility command.
You can display the status of this function and other information with the
show spanning tree
detail
command.
6.3.4.5
spanning-tree priority
Description
With this command, you configure the priority of the device. Which device becomes the root
bridge is decided based on the priority. The bridge with the highest priority becomes the root
bridge. The lower the value, the higher the priority.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals