Network structures
6.3 Spanning Tree
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
224 Configuration Manual, 11/2015, C79000-G8976-C252-10
6.3.4.4
no spanning-tree compatibility
Description
With this command, you reset the compatibility version of the protocol of the spanning tree
function to the default value.
The default value is MST.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no spanning-tree compatibility
Result
The compatibility version is reset to the default value.
Further notes
You configure the setting with the spanning-tree compatibility command.
You can display the status of this function and other information with the
show spanning tree
detail
command.
6.3.4.5
spanning-tree priority
Description
With this command, you configure the priority of the device. Which device becomes the root
bridge is decided based on the priority. The bridge with the highest priority becomes the root
bridge. The lower the value, the higher the priority.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#