Configuration
3.5 PoE
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
125
Syntax
Call up the command with the following parameter:
poe custom maxpwr <integer(0-30)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
integer
Value for the user-defined maximum
power
0 ... 30
Result
The maximum power is set.
Further notes
You enable the user-defined maximum power for the interface with the poe custom maxpwr
active
command.
You disable the user-defined maximum power for the interface with the
no poe custom
maxpwr active
command.
You delete the user-defined maximum power for the interface with the
no poe custom maxpwr
command.
3.5.3.5
no poe custom maxpwr
Description
With this command, you delete the user-defined maximum power for a port.
Requirement
You are in the Interface Configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-Gi$-$)#
The placeholders $-$ stand for the numbering of the interface.
Syntax
Call the command without parameters:
no poe custom maxpwr
Result
The user-defined maximum power is deleted.