Network protocols
7.11 ARP
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
382 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call up the command with the following parameters:
arp timeout <seconds(30-86400)>
The parameter has the following meaning:
Parameter
Description
Range of values /
note
seconds
Value for the timeout in seconds 30 ... 86400
Default: 300
Result
The setting for the timeout setting of the ARP cache is configured.
Further notes
You can reset the timeout setting to the default with the no arp timeout command.
You can display the status of this function and other information with the
show ip arp
command.
7.11.2.4
no arp timeout
Description
With this command, you reset the timeout setting of the ARP cache back to the default value.
The default value for the timeout setting is 300 seconds.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no arp timeout
Result
The timeout setting for the ARP cache is reset to the default value.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals