Diagnostics
12.1 Event and fault handling
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
778 Configuration Manual, 11/2015, C79000-G8976-C252-10
Call up the command with the following parameters:
link {up|down}[{<interface-type><interface-id>}]
The parameters have the following meaning:
Only the establishment of a connection
-
Only a break on a connection is sig-
naled
-
Type or speed of the interface
Enter a valid interface.
Module no. and port no. of the interface
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 39)".
If you do not select an interface, the function is enabled for all available interfaces.
The settings for monitoring the physical network connections have been configured.
You display the setting with the show events faults config command.
You disable the function with the
no link command.
With this command, you disable the monitoring of the physical network connections for cable
breaks or for pulling of the connector.
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#