Configuration
3.5 PoE
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
118 Configuration Manual, 11/2015, C79000-G8976-C252-10
Further notes
You save changes to the configuration in the Trial mode with the write startup-config
command.
You disable the function with the
no auto-save command.
You can display the status of this function and other information with the
show device
information
command.
3.4.3.2
no auto-save
Description
With this command, you disable the auto save function.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no auto-save
Result
The auto save function is disabled. The Trial mode is activated.
Further notes
You enable the function with the auto-save command.
You can display the status of this function and other information with the
show device
information
command.
You save changes to the configuration in the Trial mode with the
write startupconfig
command.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals