Layer 3 functions
9.6 RIPv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
602 Configuration Manual, 11/2015, C79000-G8976-C252-10
The parameters have the following meaning:
Parameter
Description
Range of values / note
1
Only routing information corresponding
to RIPv1 (RFC 1058) is evaluated and
sent.
Routing information is only dis-
tributed and received using
broadcasts.
2
Only routing information corresponding
to RIPv2 (RFC 2453) is evaluated and
sent.
Routing information is only dis-
tributed and received using mul-
ticasts (224.0.0.9).
12
Only routing information corresponding
to RIPv1 and RIPv2 is evaluated and
sent.
Routing information is distributed
and received using broadcasts
and multicasts (224.0.0.9).
Default setting
none
There is no processing of routing in-
formation using RIP.
-
Result
It has been specified which RIP packets will be processed.
9.6.3.13
no version
Description
The updating of route information is according to RIPv1 or RIPv2 (default for this parameter)
Requirement
You are in the RIPv2 Router configuration mode.
The command prompt is as follows:
cli(config-rip)#
Syntax
Call the command without parameter assignment:
no version
Result
Both RIPv1 and RIPv2 packets are processed.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals