Network protocols
7.1 IPv4 protocol
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
266 Configuration Manual, 11/2015, C79000-G8976-C252-10
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ip route <prefix> <mask> <next-hop> [<distance(1-255)>]
The parameter has the following meaning:
Parameter
Description
Range of values / note
prefix
Specifies the IP address or the address
range
specify a valid IP address
mask
Specifies the subnet mask used for
prefix.
Use decimal notation.
enter a valid subnet mask
next-hop
Specifies the IP address to which the
selected addresses will be forwarded.
specify a valid IP address
distance
The value for the administrative dis-
tance.
1 ... 255
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 39)".
Result
The entry in the IP routing table is configured.
Further notes
You delete an entry from the IP routing table with the no ip route command.
You display the IP routing table with the
show ip route command.
7.1.2.2
no ip route
Description
With this command, you delete a static entry from the IP routing table.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals