System time
5.4 PTP Client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
164 Configuration Manual, 11/2015, C79000-G8976-C252-10
5.4.2.3
ptp time diff
Description
With this command, you set the time zone for the Precision Time Protocol.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ptp time diff <(+/-hh:mm)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
+/-hh:mm
The value for the time difference. Hours and minutes specified in
the format +/-HH:MM
Result
The time zone for the Precision Time Protocol is specified.
5.4.2.4
ptp transparent-clock configuration
Description
With this command you change to the PT Transparent Clock configuration mode.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
ptp transparent-clock configuration