EasyManuals Logo

Siemens SCALANCE XR-500 Configuration Manual

Siemens SCALANCE XR-500
832 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #755 background imageLoading...
Page #755 background image
Security and authentication
11.7 Port Based Network Access Control
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
755
11.7.3.15
dot1x reauthentication
Description
With this command, you enable the 802.1x Re-Authentication function for the selected
interface. When the function is enabled, the authenticator repeats authentication of the client
periodically,
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
dot1x reauthentication
Result
Periodic authentication is enabled for the selected interfaces.
Further notes
You disable the function with the no dot1x reauthentication command.
You can display the status of this function and other information with the
show
dot1x
command.
11.7.3.16
no dot1x reauthentication
Description
With this command, you disable the function that repeats the authentication of the client by
the authenticator periodically.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals