Network protocols
7.8 SMTP Client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
370 Configuration Manual, 11/2015, C79000-G8976-C252-10
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
smtp-server { ipv4 <ucast_addr> | fqdn-name <FQDN> | ipv6 <ip6_addr> } <receiver
mail-address>
The parameters have the following meaning:
Parameter
Description
Note on the range if values
ipv4
Keyword for an IPv4 address
-
ucast_addr
IPv4 address of the SMTP server Enter a valid IPv4 unicast ad-
dress.
fqdn-name
Keyword for a domain name
-
FQDN
Domain name (Fully Qualified Domain
Name)
Maximum of 100 characters
ipv6
Keyword for an IPv6 address
-
ip6_addr
IPv6 address of the SMTP server
Enter a valid IPv6 address.
receiver mail-
address
Name of the recipient Maximum of 100 characters
For information on addresses and interfaces, refer to the section "Addresses and interface
names (Page 39)".
Result
An entry for the SMTP server is configured.
Further notes
You delete an SMTP server entry with the no smtp-server command.
7.8.2.2
no smtp-server
Description
With this command, you delete an SMTP server entry.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals