Configuration
3.1 System
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
64 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call up the command with the following parameters:
show ipv6 interface [{vlan <id> | <interface-type> <interface-id>} [prefix]]
The parameters have the following meaning:
Parameter
Description
Range of values / note
vlan
Keyword for a VLAN connection
-
id
Number of the addressed VLAN 1 ... 4094
interface-
type
Type or speed of the interface Enter a valid interface
interface-id
Module no. and port no. of the interface
prefix
shows the prefix information of the IPv6 interface
-
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 39)".
If you do not select any parameter from the parameter list, the configuration is displayed for
all available IPv6 interfaces.
Result
The configuration is displayed.
Further notes
You enable IPv6 on the VLAN interface or on the router port with the ipv6 enable command.
You configure an IPv6 address with the
ipv6 address command.
3.1.1.11
show pnio
Description
This command shows the current PROFINET IO configuration.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals