Security and authentication
11.6 Management Access Control List
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
738 Configuration Manual, 11/2015, C79000-G8976-C252-10
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
no authorized-manager
Result
The authorized manager is deactivated.
Further notes
You enable the function with the authorized-manager command.
11.6.2.3
authorized-manager ip-source
Description
With this command, you configure the interfaces and protocols via which an authorized
manager is allowed to access the device.