EasyManua.ls Logo

Siemens SCALANCE XR-500

Siemens SCALANCE XR-500
832 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diagnostics
12.1 Event and fault handling
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
776 Configuration Manual, 11/2015, C79000-G8976-C252-10
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
power [{L1|L2}]
The parameters have the following meaning:
Parameter
Description
L1
Monitoring of power supply 1
L2
Monitoring of power supply 2
If you do not select any parameters from the parameter list, the default value "L1 and L2" is
used.
Result
The setting for monitoring the power supplies is configured.
Further notes
You can display the current setting with the show events faults config command.
You disable the function with the
no power command.
12.1.6.9
no power
Description
With this command, you disable the monitoring of the power supplies.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Related product manuals